Start-up from the frozen state of two-phase thermosiphons.
Author(s) : IMURA H., KOITO Y., MOCHIZUKI M., et al.
Type of article: Article
Summary
In a cold region, ethylene glycol or propylene glycol aqueous solution is usually used as the working fluid of thermosiphons, because when pure water is used as the working fluid, the thermosiphon tube breaks due to the volume expansion of ice when water freezes into ice. If a non-freeze working fluid is required, for example under the environmental temperature of -20 °C, around 37 mass% ethylene glycol aqueous solution must be used. Usually, two-phase heat transfer coefficients of binary mixtures become lower than a pure liquid. As the concentration of ethylene glycol increases, the freezing point lowers, and then the heat transfer coefficient also lowers. Therefore, if the small concentration of ethylene glycol is used, the degradation in heat transfer may be small. In the study, 1-40 mass% ethylene glycol aqueous solutions were prepared, and were poured into glass test tubes, respectively. These glass test tubes were immersed in ethanol of -20 to -40 °C, which were cooled down by a refrigerator. Consequently, the test tube with pure water was cracked and broken, but the other test tubes were not broken even in the case of 1 mass% concentration. Since the above fact was found, the start-up experiment from the frozen state of the two-phase thermosiphon was carried out using 1 and 2 mass% ethylene glycol aqueous solutions as the working fluid. As a result, it was revealed that these thermosiphons started up smoothly without any troubles.
Details
- Original title: Start-up from the frozen state of two-phase thermosiphons.
- Record ID : 2006-0781
- Languages: English
- Source: Applied Thermal Engineering - vol. 25 - n. 17-18
- Publication date: 2005/12
Links
See other articles in this issue (18)
See the source
Indexing
-
Frigoporteurs : les fluides à base de formiates...
- Author(s) : LE PELLEC C.
- Date : 1999/06
- Languages : French
- Source: MAD Outil Froid - n. 12
View record
-
Etude expérimentale de la cristallisation des f...
- Author(s) : CHEGNIMONHAN V., BONJOUR J., AYEL V., et al.
- Date : 2005/10
- Languages : French
- Source: Revue générale du Froid & du Conditionnement d'air - n. 1057
View record
-
Study on fundamental characteristics of ice slu...
- Author(s) : SAITO A., KUMANO H., OKAWA S., et al.
- Date : 2005
- Languages : Japanese
- Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 22 - n. 1
View record
-
Analisi termo-economica dei fluidi secondari bi...
- Author(s) : UBESTE
- Date : 2007/02
- Languages : Italian
- Source: Zero sotto Zero - n. 1
View record
-
The current trends and extensive view of functi...
- Author(s) : INABA H.
- Date : 2005/02
- Languages : Japanese
- Source: Refrigeration - vol. 80 - n. 928
View record