Thermal properties of cooked beef as affected by vacuum cooling and conventional cooling.
Author(s) : SUN D. W., MCDONALD K.
Summary
Four cooling methods, i.e. vacuum cooling, air blast cooling, immersion cooling and cold storage, were used to cool cooked beef. The thermal conductivity, specific heat and thermal diffusivity of the cooled samples were determined and the data were compared with the uncooled sample. These properties were significantly affected by loss of moisture due to the cooling treatment, particularly vacuum cooled samples, which had lower thermal conductivity, specific heat and thermal diffusivity than all other treatments as a direct result of high moisture loss due to the cooling method.
Available documents
Format PDF
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Thermal properties of cooked beef as affected by vacuum cooling and conventional cooling.
- Record ID : 2004-2380
- Languages: English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Publication date: 2003/08/17
Links
See other articles from the proceedings (398)
See the conference proceedings
Indexing
-
Experimental comparison of cooling commercial l...
- Author(s) : SUN D. W., WANG L.
- Date : 2003/08/17
- Languages : English
- Source: 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
- Formats : PDF
View record
-
THE THERMAL PROPERTIES OF FROZEN INVERT SUGAR S...
- Author(s) : KEPPELER R. A., ARBOLEDA J. R.
- Date : 1982
- Languages : English
- Source: J. Food Process Eng. - vol. 5 - n. 2
View record
-
THE APPARENT SPECIFIC HEAT AND ENTHALPY OF FATT...
- Author(s) : MORLEY M. J., FURSEY G. A. J.
- Date : 1988/10
- Languages : English
- Source: Int. J. Food Sci. Technol. - vol. 23 - n. 5
View record
-
Enthalpy, heat capacity and thermal conductivit...
- Author(s) : TOCCI A. M., FLORES E. S. E., MASCHERONI R. H.
- Date : 1997
- Languages : English
- Source: Lebensm.-Wiss. Technol. - vol. 30 - n. 2
View record
-
Analysis of cooling performance of slow air, ai...
- Author(s) : WANG L. J., SUN D. W.
- Date : 2001/03/28
- Languages : English
- Source: Rapid Cooling of Food.
- Formats : PDF
View record