Summary
Air conditioning system accounts for 30%-50% of the whole yearly energy consumption in a cigarette factory. The energy saving for air-conditioning system is of great importance. Five cities in different climate regions are selected as typical cases for the cooling/heating load calculation of cigarette factories. The hourly sensible and latent loads are simulated by an architecture load calculation tool, DeST. According to this, a new central air conditioning system based on energy-bus and integrated refrigeration system with thermosyphon function is proposed. This system takes the water loop as the energy distribution bus and the terminals are direct-expansion water cooling/heating air handling units with thermosyphon function. Hangzhou, a city in middle China, is taken as the example to simulate the energy consumption of the new and the existing systems. It is shown that compared to the existing system, 20% of the energy consumption can be saved by adopting this new system in Hangzhou.
Available documents
Format PDF
Pages: 8 p.
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: A novel central air conditioning system based on energy-bus and integrated refrigeration system with thermosyphon function for cigarette factory.
- Record ID : 30002043
- Languages: English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Publication date: 2011/08/21
Links
See other articles from the proceedings (569)
See the conference proceedings
Indexing
-
Investigation on diverse loop cooling system co...
- Author(s) : WANG B., WANG F., ZHAN B., SHAO S.
- Date : 2023/08/21
- Languages : English
- Source: Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
View record
-
Using cooling load forecast as the optimal oper...
- Author(s) : LU Y. Y., CHEN J., LIU T. C., et al.
- Date : 2011/12
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 8
- Formats : PDF
View record
-
Research on pre-cooling energy saving of data c...
- Author(s) : YAN H.
- Date : 2015/05
- Languages : Chinese
- Source: HV & AC - vol. 45 - n. 303
- Formats : PDF
View record
-
Energy saving research of dedicated hydroelectr...
- Author(s) : LIN C., YI X., OUYANG T., et al.
- Date : 2014/03
- Languages : Chinese
- Source: HV & AC - vol. 44 - n. 288
- Formats : PDF
View record
-
Air conditioning system design of Wuxi Hongshan...
- Author(s) : WANG J., LAO Y.
- Date : 2011/10
- Languages : Chinese
- Source: HV & AC - vol. 41 - n. 255
- Formats : PDF