TESTS WERE CARRIED OUT ON SOME PERISHABLE BAKERY PRODUCTS TO DETERMINE BEHAVIOUR DURING FREEZING. THESE PRODUCTS APPEAR TO FREEZE BETWEEN 270 AND 263 K (-3 AND -10 DEG C). STORAGE EXPERIMENTS AT A TEMPERATURE OF 269 K (-4 DEG C) FOR ONE WEEK, HAVE SHOWN EXCELLENT BACTERIAL STABILITY, BUT A CONSIDERABLE REDUCTION IN SENSORY QUALITY. PRESERVATION AND STORAGE AT 269 K OFFER INTERESTING BUT LIMITED POSSIBILITIES, A CONDITION BEING THATTHESE PRODUCTS HAVE A FREEZING POINT BELOW ZERO, AND THAT THEY ARE PROPERLY PACKED.