Retrofitting of R12 and R502 refrigerating systems to alternative refrigerants.
Type of article: Periodical article
Summary
ASERCOM has published guidelines for retrofitting R12 and R502 systems with substitute refrigerants. For systems functioning correctly and with no leakage, it is suggested that a new refrigerant is not immediately necessary. Before a change is made, a series of system checks are suggested. R134a is the only single substance, others are blends. Blends containing R22 are easier to use as oil change is not necessary, but R22 will eventually be unobtainable. Change to R134a or any HFC blends involves a change to an ester based oil and possibly material changes in the system. All pipe joints from the expansion valve through the compressor must be brazed or welded. Attention is given to removing all traces of original oil and system cleaning in general. D.W.H.
Details
- Original title: Retrofitting of R12 and R502 refrigerating systems to alternative refrigerants.
- Record ID : 1996-0060
- Languages: English
- Source: ASERCOM, Tech. Inf. - n. 3
- Publication date: 1994
- Document available for consultation in the library of the IIR headquarters only.
Links
See the source
Indexing
-
Themes:
CFCs;
HCFCs;
HFCs;
Lubricants;
Blends;
Containment, refrigerant charge reduction - Keywords: R134a; Filter; CFC; Maintenance; Lubrication; Recommendation; R502; R22; R12; Substitute; Mixture; Desiccant; Retrofitting; Leakage; Refrigerant; Refrigerant charge
-
The use of mixtures in refrigerating plants.
- Author(s) : CAMPAGNA E.
- Date : 1995/06/16
- Languages : Italian
- Source: I nuovi refrigeranti ed il settore alimentare. Le ultime tecnologie e il futuro del freddo e del condizionamento. / The new refrigerants and the food industry.The future of refrigeration and air conditioning.
View record
-
Retrofit e reclaiming: le soluzioni ai problemi...
- Author(s) : CAMPAGNA E., CHIESA L.
- Date : 1997/06/27
- Languages : Italian
- Source: Le ultime tecnologie del freddo e del condizionamento./ Latest technologies in refrigeration and air conditioning.
View record
-
Zeotropic refrigerants in the real world: perfo...
- Author(s) : BRESNAHAN J. D., LOW R. E.
- Date : 1995/05/01
- Languages : English
- Source: 1995 AIRAH Conference Proceedings.
View record
-
A SPECIALIST REFRIGERANT RECOVERY/RECLAIM SERVI...
- Author(s) : O'GORMAN T.
- Date : 1990
- Languages : English
View record
-
LA RECUPERATION AU QUOTIDIEN.
- Author(s) : MITEV P.
- Date : 1990
- Languages : French
- Source: J. RPF - n. 719
View record