Simulation and performance analysis of basic GAX and advanced GAX cycles with ammonia-water and ammonia-water-lithium bromide absorption fluids.
Author(s) : ZALTASH A., GROSSMAN G.
Summary
The potential consequences of using a ternary mixture of ammonia-water-lithium bromide in the generator absorber heat exchange (GAX) and Branched GAX are discussed in the study. A modular, steady state absorption simulation model was used to investigate the potential of combining the above cycles with the new fluids. Performance parameters of the cycles, including COP and heat duties, were investigated as functions of different operating parameters in the cooling mode for both the ammonia-water binary and the ammonia-water-lithium bromide ternary mixtures. High performance potential of GAX and Branched GAX cycles using the ternary fluid mixture was achieved especially at the high range of firing temperatures exceeding 204 deg C. The cooling COP's have been improved by approximately 21%.
Details
- Original title: Simulation and performance analysis of basic GAX and advanced GAX cycles with ammonia-water and ammonia-water-lithium bromide absorption fluids.
- Record ID : 1998-0232
- Languages: English
- Source: Ab-sorption 96. Towards sustainable technologies. Proceedings./ Ab-sorption 96. Vers les technologies durables. Comptes rendus.
- Publication date: 1996/09/17
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (115)
See the conference proceedings
Indexing
-
Thermodynamic comparison of water-based working...
- Author(s) : SARAVANAN R., MAIYA M. P.
- Date : 1998/07
- Languages : English
- Source: Applied Thermal Engineering - vol. 18 - n. 7
View record
-
VX GAX cycle development.
- Author(s) : ERICKSON D. C., ANAND G.
- Date : 1996/09/17
- Languages : English
- Source: Ab-sorption 96. Towards sustainable technologies. Proceedings./ Ab-sorption 96. Vers les technologies durables. Comptes rendus.
View record
-
Production de froid à partir de chaleur basse t...
- Author(s) : LARGER D.
- Date : 1997/03
- Languages : French
- Source: Rev. gén. Froid - vol. 87 - n. 971
View record
-
Performance comparison of a bubble absorber wit...
- Author(s) : ORONEL C., AMARIS C., VALLÈS M., et al.
- Date : 2011/04/06
- Languages : English
- Source: Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
View record
-
Single-effect/double-lift chiller: résumé of op...
- Author(s) : SCHWEIGLER C., ZIEGLER F.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record