Condensation of refrigerants in horizontal microfin tubes: comparison of prediction methods for heat transfer.
Author(s) : WANG H. S., HONDA H.
Summary
The refrigerants tested were R11, R123, R134a, R22 and R410A. Experimental data for six tubes with an inside diameter at fin root of 6.49 to 8.88 mm, fin height of 0.16 to 0.24 mm, fin pitch of 0.34 to 0.53 mm and helix angle of groove of 12-20 °C were adopted. The r.m.s. error of the predictions for all tubes and all refrigerants decreased in order of the correlations proposed by Cavallini et al. (1995), Shikazono et al. (1998, Luu and Bergles (1980), Kedzierski and Goncalves (1999), Yu and Koyama (1998), and the theoretical model proposed by Wang et al. (2001).
Available documents
Format PDF
Pages: 2001-5
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Condensation of refrigerants in horizontal microfin tubes: comparison of prediction methods for heat transfer.
- Record ID : 2003-0672
- Languages: English
- Source: Thermophysical Properties and Transfer Processes of New Refrigerants.
- Publication date: 2001/10/03
Links
See other articles from the proceedings (60)
See the conference proceedings
Indexing
-
Themes:
HCFCs;
HFCs;
Mass transfer;
Blends - Keywords: R410A; R134a; Horizontal tube; Extended surface; Comparison; Calculation; Microfin tube; Measurement; Mass transfer; Heat transfer; R22; R123; Miniaturization; Refrigerant; Condensation
-
Condensation of refrigerants in horizontal micr...
- Author(s) : WANG H. S., HONDA H.
- Date : 2003/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 4
- Formats : PDF
View record
-
Condensation of refrigerants in horizontal micr...
- Author(s) : WANG H. S., ROSE J. W., HONDA H.
- Date : 2003/06
- Languages : English
- Source: International Journal of Refrigeration - Revue Internationale du Froid - vol. 26 - n. 4
- Formats : PDF
View record
-
A correlation of forced convective boiling heat...
- Author(s) : MOMOKI S., YU J., KOYAMA S., FUJII T., HONDA H.
- Date : 1995
- Languages : Japanese
- Source: Trans. JAR - vol. 12 - n. 2
View record
-
Nucleate boiling performance of R22, R123, R134...
- Author(s) : WANG C. C., SHIEH W. Y., CHANG Y. J.
- Date : 1998
- Languages : English
- Source: ASHRAE Transactions. 1998 Winter Meeting, San Francisco, CA.
View record
-
New correlation methods of evaporation heat tra...
- Author(s) : MAKISHI O., HONDA H.
- Date : 2005
- Languages : Japanese
- Source: Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers - vol. 22 - n. 4
View record