DETERMINATION OF SHRINKAGE LOSSES IN COLD ROOMS FOR FROZEN MEAT.

[In Russian. / En russe.]

Author(s) : ROTGOL'C E. A.

Type of article: Article

Summary

FORMULAE ARE GIVEN FOR THE DETERMINATION, IN COLD ROOMS FOR FROZEN MEAT, OF AIR RELATIVE HUMIDITY PARAMETERS AND OF THE MAGNITUDES OF SHRINKAGE LOSSES. FOR THE SELECTION OF FORMULAE THE SPECIFIC CHARACTERISTICS OF ROOM STRUCTURES WERE CONSIDERED (DIMENSIONS, TYPE AND THICKNESS OF INSULATION, ARRANGEMENT OF COOLING UNITS, ETC) AND THEIR OPERATING CONDITIONS. THE RELATIONSHIPS PROPOSED CAN BE USED FOR OPTIMISING THE COOLING SYSTEM OF COLD ROOMS FOR THE CALCULATION OF THE EXPENSES DUE TO SHRINKAGE LOSSES.