Simulation of heat transfer in CO2 and nitrogen freezers.

[In German. / En allemand.]

Author(s) : BALDUHN R., ENGELHORN H. R.

Type of article: Article

Summary

Investigations were performed with an electrically heated tube in which cryogenic CO2 and nitrogen were circulating. The cryogens were tested not only at a gaseous state, but also at gas-snow (CO2) and gas-liquid state (nitrogen). The highest heat fluxes amounted to about 50 kilowatts/m2. The highest heat transfer coefficients of about 4 kilowatts/m2.K were measured with boiling nitrogen.

Details

  • Original title: [In German. / En allemand.]
  • Record ID : 1995-0934
  • Languages: German
  • Source: KI Luft Kältetech. - vol. 30 - n. 7
  • Publication date: 1994/07
  • Document available for consultation in the library of the IIR headquarters only.

Links


See other articles in this issue (4)
See the source