Overview of the use of refrigerants in thermodynamic machines.
Panorama de l'utilisation des fluides frigorigènes dans les machines thermodynamiques.
Author(s) : BERNIER J.
Summary
The author analysed the different criteria for choosing a particular R22 substitute, including: condensation pressure, discharge temperature, volumetric efficiency of the compressor, volumetric refrigerating capacity, COP, evaporating temperature variation, global warming potential, toxicity, inflammability and explosiveness. A comparison was done for a high-performance, single-stage hermetic compressor with a swept volume of 10 m3/h at a constant condensation temperature of 40 deg C, a superheat of 5 deg C and a sub-cooling temperature of 3 deg C.
Details
- Original title: Panorama de l'utilisation des fluides frigorigènes dans les machines thermodynamiques.
- Record ID : 1997-3220
- Languages: French
- Subject: Environment, General information
- Source: Remplacement des CFC dans les systèmes thermodynamiques.
- Publication date: 1996/06/12
- Document available for consultation in the library of the IIR headquarters only.
Links
See other articles from the proceedings (4)
See the conference proceedings
Indexing
-
Themes:
Refrigerants, secondary refrigerants: general information;
CFCs;
HFCs;
General information on environment (climate change, ozone depletion…);
Ammonia;
Hydrocarbons;
Blends - Keywords: R410A; R407C; R134a; CFC; Toxicity; Ammonia; R404A; Thermodynamic property; Review; Substitute; Propane; Flammability; Greenhouse effect; COP; Refrigerant
-
Alternative refrigerants for refrigeration and ...
- Author(s) : STEIMLE F.
- Date : 1999/09/19
- Languages : English
- Source: 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Formats : PDF
View record
-
Development of a new refrigerant.
- Author(s) : MISAKI S., SEKIYA A.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record
-
R22-Ausstieg: aus internationaler Sicht.
- Author(s) : REINER G.
- Date : 1998/11/18
- Languages : German
- Source: DKV-Tagungsbericht 25. 1998, Würzburg.
View record
-
CFCs Substitutes: new threats for the ozone lay...
- Author(s) : NOVELLI I.
- Date : 1994/09/21
- Languages : English
- Source: CFCs, the Day After.
- Formats : PDF
View record
-
Supermarkets enhance systems to reduce TEWI imp...
- Author(s) : LIKES P. W.
- Date : 1995/10/23
- Languages : English
- Source: Stratospheric Ozone Protection for the 90's. 1995 International CFC and Halon Alternatives Conference & Exhibition. Conference proceedings.
View record